{"product_id":"fanuc-a81l-0001-0157-ac-line-reactor","title":"FANUC A81L-0001-0157 AC Line Reactor","description":"\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eFANUC A81L-0001-0157 AC Line Reactor\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ctable style=\"width: 101.301%; height: 518.586px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 25px; text-align: left;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 25px; text-align: left;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 25px; text-align: left;\"\u003eFANUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.5225%; text-align: left; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; text-align: left; height: 19.5938px;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eA81L-0001-0157\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23px; text-align: left;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 23px;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eHanding time\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 23px;\"\u003ewithin 1-2 working days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.75px; text-align: left;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 26.75px;\"\u003e\u003cstrong\u003eShipping Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 26.75px;\"\u003eDHL\/UPS\/FedEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 213.562px;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 213.562px;\"\u003e\u003cstrong\u003eEstimated Delivery Time (via DHL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 213.562px;\"\u003e\n\u003cp\u003eAsia: 1-3 business days\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eEurope: 2-4 business days\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eNorth America: 2-4 business days\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSouth America:  3-6 business days\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMiddle East \u0026amp; Africa: 3-6 business days\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOceania: \u003cmeta charset=\"utf-8\"\u003e2-5 business days\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 71.1875px;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 71.1875px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 71.1875px;\"\u003eNEW\/Refurbished: 1-Year warranty\u003cbr\u003eUsed(90% New): 3-Month warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 19.5938px;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eAC Line Reactor\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 73.555px;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 73.555px;\"\u003e\u003cstrong\u003eParameter Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 73.555px;\"\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eA81L00010157\u003cbr\u003eAC Line Reactor\u003cbr\u003eCNC\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.75px;\"\u003e\n\u003ctd style=\"width: 41.5225%; height: 26.75px; text-align: left;\"\u003e\u003cstrong\u003eService\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; height: 26.75px; text-align: left;\"\u003eTest video will be sent before delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 41.5225%; text-align: left; height: 19.5938px;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003ePacking\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 58.1315%; text-align: left; height: 19.5938px;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eCartons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-695e672e-c9e8-832a-95b3-03e8494aa081-0\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-695e672e-c9e8-832a-95b3-03e8494aa081-0\" data-turn-id-container=\"request-695e672e-c9e8-832a-95b3-03e8494aa081-0\" data-testid=\"conversation-turn-742\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-15 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"d19e99cc-fbe8-4cb6-a56a-e860dcd9417b\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-6-thinking\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"f09fd988-ff0f-4c4b-bf81-1a540b8eb2e3\" dir=\"auto\" data-message-model-slug=\"gpt-5-6-thinking\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp data-start=\"948\" data-end=\"1089\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"952\" data-end=\"976\"\u003eFANUC A81L-0001-0157\u003c\/strong\u003e is a three-phase \u003cstrong data-start=\"994\" data-end=\"1088\"\u003eAC reactor specified for compatible FANUC PSM-26i and αi PS 26 power supply configurations\u003c\/strong\u003e.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1091\" data-end=\"1373\"\u003eFANUC’s αi-Series amplifier documentation lists this exact part number as the standard AC reactor for the \u003cstrong data-start=\"1197\" data-end=\"1219\"\u003ePSM-26i \/ αi PS 26\u003c\/strong\u003e power supply module. It is installed as part of the main AC input circuit for the regenerative power supply system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1375\" data-end=\"1604\"\u003eFANUC’s later αi-B documentation also lists the A81L-0001-0157 as the \u003cstrong data-start=\"1445\" data-end=\"1501\"\u003eearlier IP1X reactor specification for the αiPS 26-B\u003c\/strong\u003e, while A81L-0001-0186 is identified as the current IP2X version. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1606\" data-end=\"1666\"\u003eThis product is commonly searched for under names including:\u003c\/p\u003e\n\u003cul data-start=\"1668\" data-end=\"1819\"\u003e\n\u003cli data-section-id=\"1ohd2n\" data-start=\"1668\" data-end=\"1701\"\u003eFANUC A81L-0001-0157 AC Reactor\u003c\/li\u003e\n\u003cli data-section-id=\"y00x7\" data-start=\"1702\" data-end=\"1730\"\u003eFANUC PSM-26i Line Reactor\u003c\/li\u003e\n\u003cli data-section-id=\"11z7184\" data-start=\"1731\" data-end=\"1755\"\u003eFANUC αi PS 26 Reactor\u003c\/li\u003e\n\u003cli data-section-id=\"csqh9p\" data-start=\"1756\" data-end=\"1787\"\u003eFANUC αiPS 26-B Input Reactor\u003c\/li\u003e\n\u003cli data-section-id=\"1qm5qjt\" data-start=\"1788\" data-end=\"1819\"\u003eFANUC Three-Phase CNC Reactor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1821\" data-end=\"2073\"\u003eThese names are consistent with FANUC documentation and established industrial-parts terminology. The product should not be classified as a servo amplifier, power supply module, PCB, or general-purpose transformer. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2075\" data-end=\"2286\"\u003eThe reactor is suitable for replacement when the original A81L-0001-0157 has confirmed winding damage, overheated terminals, damaged insulation, abnormal physical condition, or another verified electrical fault.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"2288\" data-end=\"2453\"\u003e\n\u003cstrong data-start=\"2290\" data-end=\"2344\"\u003eInspected and electrically checked before shipment\u003c\/strong\u003e\u003cbr data-start=\"2344\" data-end=\"2347\"\u003e\u003cstrong data-start=\"2349\" data-end=\"2405\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2288\" data-end=\"2453\"\u003e\n\u003cstrong data-start=\"2349\" data-end=\"2405\"\u003eExact part number and label verified before dispatch\u003c\/strong\u003e\u003cbr data-start=\"2405\" data-end=\"2408\"\u003e\u003cstrong data-start=\"2411\" data-end=\"2453\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2288\" data-end=\"2453\"\u003e\u003cstrong data-start=\"2411\" data-end=\"2453\"\u003eWorldwide DHL, UPS, and FedEx shipping\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2455\" data-end=\"2458\"\u003e\n\u003ch4 data-start=\"2460\" data-end=\"2480\"\u003eProduct Details\u003c\/h4\u003e\n\u003cul data-start=\"2482\" data-end=\"3180\"\u003e\n\u003cli data-section-id=\"1c1nf4m\" data-start=\"2482\" data-end=\"2496\"\u003eBrand: FANUC\u003c\/li\u003e\n\u003cli data-section-id=\"1xpei0w\" data-start=\"2497\" data-end=\"2526\"\u003ePart Number: A81L-0001-0157\u003c\/li\u003e\n\u003cli data-section-id=\"u15vqw\" data-start=\"2527\" data-end=\"2561\"\u003eAlternative Format: A81L00010157\u003c\/li\u003e\n\u003cli data-section-id=\"1t3v76m\" data-start=\"2562\" data-end=\"2597\"\u003eOfficial Product Type: AC Reactor\u003c\/li\u003e\n\u003cli data-section-id=\"1yurc3n\" data-start=\"2598\" data-end=\"2636\"\u003eCommon Product Name: AC Line Reactor\u003c\/li\u003e\n\u003cli data-section-id=\"dptfxu\" data-start=\"2637\" data-end=\"2688\"\u003eApplicable Power Supply: FANUC PSM-26i \/ αi PS 26\u003c\/li\u003e\n\u003cli data-section-id=\"qezujh\" data-start=\"2689\" data-end=\"2736\"\u003eαi-B Reference: Earlier Reactor for αiPS 26-B\u003c\/li\u003e\n\u003cli data-section-id=\"nxf3q5\" data-start=\"2737\" data-end=\"2770\"\u003eInput-System Class: 200V Series\u003c\/li\u003e\n\u003cli data-section-id=\"1vbslsh\" data-start=\"2771\" data-end=\"2806\"\u003eMain-Circuit Type: Three-Phase AC\u003c\/li\u003e\n\u003cli data-section-id=\"25rv73\" data-start=\"2807\" data-end=\"2847\"\u003eAssociated Power-Supply Capacity: 26kW\u003c\/li\u003e\n\u003cli data-section-id=\"17tn1rs\" data-start=\"2848\" data-end=\"2881\"\u003eReference Heat Dissipation: 70W\u003c\/li\u003e\n\u003cli data-section-id=\"1twxonn\" data-start=\"2882\" data-end=\"2930\"\u003eOfficial Reference Weight: Approximately 9.5kg\u003c\/li\u003e\n\u003cli data-section-id=\"lxkw9u\" data-start=\"2931\" data-end=\"2979\"\u003eProtection Version: Earlier IP1X Specification\u003c\/li\u003e\n\u003cli data-section-id=\"58iod9\" data-start=\"2980\" data-end=\"3028\"\u003eLater Documented Version: A81L-0001-0186, IP2X\u003c\/li\u003e\n\u003cli data-section-id=\"cxkswa\" data-start=\"3029\" data-end=\"3056\"\u003eProduct Series: A81L-0001\u003c\/li\u003e\n\u003cli data-section-id=\"1c6nfxk\" data-start=\"3057\" data-end=\"3122\"\u003eApplication: Compatible FANUC Regenerative Power Supply Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ppj88q\" data-start=\"3123\" data-end=\"3180\"\u003eCategory: FANUC AC Reactor \/ CNC Power-System Component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3182\" data-end=\"3361\"\u003eThe \u003cstrong data-start=\"3186\" data-end=\"3255\"\u003e26kW value refers to the applicable PSM-26i power-supply capacity\u003c\/strong\u003e, rather than independent mechanical output produced by the reactor. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3363\" data-end=\"3366\"\u003e\n\u003ch4 data-start=\"3368\" data-end=\"3404\"\u003eElectrical Rating Clarification\u003c\/h4\u003e\n\u003cp data-start=\"3406\" data-end=\"3549\"\u003eA single fixed current and inductance value should not be published for every A81L-0001-0157 without first checking the physical product label.\u003c\/p\u003e\n\u003cp data-start=\"3551\" data-end=\"3658\"\u003ePublic certification records list at least two approved constructions under the same FANUC ordering number:\u003c\/p\u003e\n\u003cul data-start=\"3660\" data-end=\"3788\"\u003e\n\u003cli data-section-id=\"140d9zy\" data-start=\"3660\" data-end=\"3704\"\u003eTAM construction: \u003cstrong data-start=\"3680\" data-end=\"3704\"\u003e110A, AC264V, 0.07mH\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kdpb3u\" data-start=\"3705\" data-end=\"3788\"\u003eTOK construction: \u003cstrong data-start=\"3725\" data-end=\"3750\"\u003e125A, AC264V, 0.055mH\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3790\" data-end=\"4020\"\u003eSome industrial replacement pages list the unit as \u003cstrong data-start=\"3841\" data-end=\"3876\"\u003e110A, 240V, three phase, 0.07mH\u003c\/strong\u003e, which appears to correspond to one specific construction rather than every possible A81L-0001-0157 unit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4022\" data-end=\"4264\"\u003eFor this reason, the safest Shopify product page should use the verified general specification above. The exact current, voltage marking, inductance and manufacturer construction can be added after confirming the label on the unit being sold.\u003c\/p\u003e\n\u003chr data-start=\"4266\" data-end=\"4269\"\u003e\n\u003ch4 data-start=\"4271\" data-end=\"4303\"\u003ePhysical Configuration Note\u003c\/h4\u003e\n\u003cp data-start=\"4305\" data-end=\"4485\"\u003eFANUC documentation shows \u003cstrong data-start=\"4331\" data-end=\"4406\"\u003etwo physical shapes under the same A81L-0001-0157 specification drawing\u003c\/strong\u003e. FANUC states that the customer cannot specify which construction is supplied.\u003c\/p\u003e\n\u003cp data-start=\"4487\" data-end=\"4538\"\u003eThe documented maximum envelopes are approximately:\u003c\/p\u003e\n\u003cul data-start=\"4540\" data-end=\"4604\"\u003e\n\u003cli data-section-id=\"1bcebf8\" data-start=\"4540\" data-end=\"4572\"\u003eShape 1: \u003cstrong data-start=\"4551\" data-end=\"4572\"\u003e128 × 155 × 165mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v4e8ej\" data-start=\"4573\" data-end=\"4604\"\u003eShape 2: \u003cstrong data-start=\"4584\" data-end=\"4604\"\u003e70 × 155 × 165mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4606\" data-end=\"4749\"\u003eBoth versions retain the same key installation and terminal-layout dimensions shown in the FANUC drawing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4751\" data-end=\"4897\"\u003eBecause the exterior shape may vary, product photographs and terminal measurements should be checked before replacing a unit solely by appearance.\u003c\/p\u003e\n\u003chr data-start=\"4899\" data-end=\"4902\"\u003e\n\u003ch4 data-start=\"4904\" data-end=\"4942\"\u003eA81L-0001-0157 and A81L-0001-0186\u003c\/h4\u003e\n\u003cp data-start=\"4944\" data-end=\"5006\"\u003eFANUC distinguishes the two reactor specifications as follows:\u003c\/p\u003e\n\u003cul data-start=\"5008\" data-end=\"5169\"\u003e\n\u003cli data-section-id=\"pscu1e\" data-start=\"5008\" data-end=\"5088\"\u003e\n\u003cstrong data-start=\"5010\" data-end=\"5029\"\u003eA81L-0001-0157:\u003c\/strong\u003e Earlier version supporting IP1X conductive-part protection\u003c\/li\u003e\n\u003cli data-section-id=\"167j1o0\" data-start=\"5089\" data-end=\"5169\"\u003e\n\u003cstrong data-start=\"5091\" data-end=\"5110\"\u003eA81L-0001-0186:\u003c\/strong\u003e Current version supporting IP2X conductive-part protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5171\" data-end=\"5358\"\u003eBoth are documented in connection with the \u003cstrong data-start=\"5214\" data-end=\"5227\"\u003eαiPS 26-B\u003c\/strong\u003e power-supply capacity, but the later version has updated protection around conductive parts. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"5360\" data-end=\"5431\"\u003eThey should not be advertised as completely identical without checking:\u003c\/p\u003e\n\u003cul data-start=\"5433\" data-end=\"5620\"\u003e\n\u003cli data-section-id=\"1026h8b\" data-start=\"5433\" data-end=\"5455\"\u003eMounting arrangement\u003c\/li\u003e\n\u003cli data-section-id=\"1mvjsi9\" data-start=\"5456\" data-end=\"5479\"\u003eTerminal construction\u003c\/li\u003e\n\u003cli data-section-id=\"bdqzj1\" data-start=\"5480\" data-end=\"5500\"\u003eCabinet clearances\u003c\/li\u003e\n\u003cli data-section-id=\"7ferkm\" data-start=\"5501\" data-end=\"5518\"\u003eCable terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1e6otmn\" data-start=\"5519\" data-end=\"5548\"\u003eOriginal electrical drawing\u003c\/li\u003e\n\u003cli data-section-id=\"1sr03tf\" data-start=\"5549\" data-end=\"5583\"\u003eApplicable FANUC manual revision\u003c\/li\u003e\n\u003cli data-section-id=\"1qgs5io\" data-start=\"5584\" data-end=\"5620\"\u003eSafety and protection requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5622\" data-end=\"5625\"\u003e\n\u003ch4 data-start=\"5627\" data-end=\"5650\"\u003eCompatibility Note\u003c\/h4\u003e\n\u003cp data-start=\"5652\" data-end=\"5702\"\u003eBefore ordering the A81L-0001-0157, please verify:\u003c\/p\u003e\n\u003cul data-start=\"5704\" data-end=\"6164\"\u003e\n\u003cli data-section-id=\"gz3z62\" data-start=\"5704\" data-end=\"5732\"\u003eComplete FANUC part number\u003c\/li\u003e\n\u003cli data-section-id=\"1wifqox\" data-start=\"5733\" data-end=\"5772\"\u003eOriginal reactor identification label\u003c\/li\u003e\n\u003cli data-section-id=\"8qnuat\" data-start=\"5773\" data-end=\"5830\"\u003ePSM-26i, αi PS 26 or applicable αiPS 26-B configuration\u003c\/li\u003e\n\u003cli data-section-id=\"9uzgxr\" data-start=\"5831\" data-end=\"5865\"\u003eEarlier IP1X reactor requirement\u003c\/li\u003e\n\u003cli data-section-id=\"1vibhvp\" data-start=\"5866\" data-end=\"5904\"\u003eThree-phase 200V-series input system\u003c\/li\u003e\n\u003cli data-section-id=\"shv0sf\" data-start=\"5905\" data-end=\"5955\"\u003eCurrent and inductance shown on the actual label\u003c\/li\u003e\n\u003cli data-section-id=\"1i1veao\" data-start=\"5956\" data-end=\"6001\"\u003eTerminal-bolt size and terminal arrangement\u003c\/li\u003e\n\u003cli data-section-id=\"ms63sc\" data-start=\"6002\" data-end=\"6027\"\u003eMounting-hole positions\u003c\/li\u003e\n\u003cli data-section-id=\"g95xb7\" data-start=\"6028\" data-end=\"6053\"\u003eAvailable cabinet space\u003c\/li\u003e\n\u003cli data-section-id=\"xo5z1z\" data-start=\"6054\" data-end=\"6109\"\u003eCondition of the connected cables and crimp terminals\u003c\/li\u003e\n\u003cli data-section-id=\"nb49q3\" data-start=\"6110\" data-end=\"6164\"\u003eWhether A81L-0001-0157 or A81L-0001-0186 is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6166\" data-end=\"6423\"\u003eFANUC assigns different AC reactor numbers to different power-supply capacities. A similar-looking A81L reactor intended for PSM-15i, PSM-30i or PSM-37i should not be selected as a substitute based only on appearance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"6425\" data-end=\"6428\"\u003e\n\u003ch4 data-start=\"6430\" data-end=\"6451\"\u003eCommon Use Cases\u003c\/h4\u003e\n\u003cul data-start=\"6453\" data-end=\"6847\"\u003e\n\u003cli data-section-id=\"et5qs9\" data-start=\"6453\" data-end=\"6503\"\u003eReplacement of a FANUC A81L-0001-0157 AC reactor\u003c\/li\u003e\n\u003cli data-section-id=\"1p6h4vr\" data-start=\"6504\" data-end=\"6550\"\u003eMaintenance of a PSM-26i power-supply system\u003c\/li\u003e\n\u003cli data-section-id=\"1dlkfpy\" data-start=\"6551\" data-end=\"6599\"\u003eRestoration of an αi PS 26 input-power circuit\u003c\/li\u003e\n\u003cli data-section-id=\"f1wqo7\" data-start=\"6600\" data-end=\"6656\"\u003eMaintenance of an earlier αiPS 26-B IP1X configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1wi1ghx\" data-start=\"6657\" data-end=\"6719\"\u003eReplacement of a reactor with damaged windings or insulation\u003c\/li\u003e\n\u003cli data-section-id=\"1cjc159\" data-start=\"6720\" data-end=\"6779\"\u003eReplacement of overheated or physically damaged terminals\u003c\/li\u003e\n\u003cli data-section-id=\"qpkprj\" data-start=\"6780\" data-end=\"6847\"\u003ePreparation of a matching spare reactor for maintenance inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6849\" data-end=\"6852\"\u003e\n\u003ch4 data-start=\"6854\" data-end=\"6874\"\u003eSales \u0026amp; Support\u003c\/h4\u003e\n\u003cp data-start=\"6876\" data-end=\"7066\"\u003eEach \u003cstrong data-start=\"6881\" data-end=\"6910\"\u003eA81L-0001-0157 AC Reactor\u003c\/strong\u003e is checked for part-number accuracy, label specifications, winding condition, insulation condition, terminal integrity and physical damage before delivery.\u003c\/p\u003e\n\u003cp data-start=\"7068\" data-end=\"7201\"\u003eThe actual current, inductance, manufacturer construction and exterior shape can be confirmed from the supplied unit before shipment.\u003c\/p\u003e\n\u003cp data-start=\"7203\" data-end=\"7379\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca rel=\"noopener\" title=\"Reliable industrial automation solutions - REACO CNC\" href=\"https:\/\/reacocnc.com\/\" target=\"_blank\"\u003eREACO CNC\u003c\/a\u003e provides warranty coverage, product-identification assistance and \u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/reacocnc.com\/pages\/contact-us\" title=\"Contact Us for Reliable industrial automation solutions - REACO CNC\" rel=\"noopener\" target=\"_blank\"\u003etechnical support\u003c\/a\u003e for FANUC reactors, power supply modules, servo amplifiers and spindle amplifiers.\u003c\/p\u003e\n\u003cp data-start=\"7381\" data-end=\"7464\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eWorldwide delivery is available through DHL, UPS, FedEx and other express carriers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FANUC","offers":[{"title":"Brand New","offer_id":49453687472343,"sku":"A81L-0001-0157-new","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0780\/3784\/4183\/files\/FANUC_A81L-0001-0157_AC_Line_Reactor.webp?v=1784185879","url":"https:\/\/reacocnc.com\/products\/fanuc-a81l-0001-0157-ac-line-reactor","provider":"REACO CNC","version":"1.0","type":"link"}