Common FANUC CNC Alarms Classification

During CNC machine operation, alarms may occasionally occur. To address these issues effectively, targeted troubleshooting and maintenance are required. This article provides a classification of common FANUC system alarms for reference, helping technicians respond correctly when problems arise.

FANUC Alarm Classification

FANUC system alarms refer to faults detected in CNC hardware or software. Alarms are classified according to their numbers as follows:

Alarm Number Range Category

000~

Programming & Operation

300~

Pulse Encoder

400~

Servo

500~

Overtravel

700~

Overheat / Temperature Exception

749~

Spindle Communication

900~

CNC System

5000~

Programming & Operation

9000~

Spindle

Examples:

  • SV0409: Torque detection abnormal
  • SV5136: FSSB amplifier shortage
  • OH0701: Fan motor stopped
  • SP9004: SSPA:04 Power phase loss / Fuse blown

Alarm Prefix Classification

Alarm Prefixes Types

PSxxxx

Program Operation Related

BGxxxx

Background Editing Related

SRxxxx

Communication Related

SWxxxx

Parameter Write Status

SVxxxx

Servo Related

OTxxxx

Overtravel Related

IOxxxx

Memory File Related

PWxxxx

Power Cut Request

SPxxxx

Spindle Related

OHxxxx

Overheat Related

DSxxxx

Other

IExxxx

Malfunction Prevention

External Alarms

External alarms are defined by machine manufacturers based on external auxiliary equipment actions. They are output through PMC programs:

Information Number Range Number Range Type Description

1000~1999

Alarm Info Page Shows

alarm info; CNC enters alarm state

2000~2099

Operation Info Page Shows

Operation Info

2100~2999

Operation Info Page Shows

Operation Info(no information number)

Only displays content, no number

Examples:

  • EX1100: EMERGENCY
  • EX1101: OVERLOAD THERMAL OR TRIP
  • SLIDE OIL LEVEL LOW
  • COUNTER COUNT UP

Note:
External alarms are manufacturer-defined and vary by model. Please refer to the machine manual for details.

Other Articles

Related Articles

Here are some related technical resources you may also find helpful:

Technical Categories

Browse our full set of technical resources: 

Back to Previous Page

Click here to return to the previous category page.

→ Back to Common alarm List

Back to Technical Support Home

Return to the Technical Support main page to explore all resources.

→ Technical Support Main Page

Get in touch with REACO CNC

Request Repair Consultation

Have a technical issue or need repair assistance?

Looking for a part quote?

Hours of Operation Mon - Fri: 8 AM to 8 PM(Beijing Time, UTC+8)

Email: sales@reacocnc.com